Current Output O₂ Sensor with Flying Wires and High Linearity

The M-06 Medical Oxygen Sensor is a high-precision, current-output electrochemical sensor designed for oxygen concentration measurement in clinical applications. Featuring flying wire connectors and a flat base housing, the M-06 offers high signal stability, low cross-sensitivity to anesthesia gases, and exceptional linearity across the full measurement range. It is engineered to meet demanding requirements for accuracy, durability, and signal consistency.


Technical Specifications:

  • Sensor Type: Current output electrochemical oxygen sensor
  • Initial Output Signal: 200 µA ± 40 µA in dry ambient air
  • Measurement Range: 0 to 100 Vol.% O₂
  • Response Time (T90): < 20 seconds
  • Expected Operating Life: > 300,000 Vol.% hours
  • Drift: < 2 % Vol. O₂/month in air, averaged over 12 months
  • Linearity Error: ≤ 3 % at 100 % O₂ (5-minute exposure)
  • Repeatability: ± 1 % Vol. O₂ at 100 % O₂ (5-minute exposure)
  • Zero Offset: < 0.4 % oxygen equivalent at 25 °C in 100 % N₂ (3-minute exposure)
  • Operating Temperature Range: 10 to 40 °C
  • Recommended Temperature Range: 5 to 30 °C
  • Maximum Temperature Range: -20 to 50 °C (≤10 hours)
  • Pressure Range: 700 to 1250 hPa
  • Humidity Range: Up to 100 % RH, non-condensing
  • Influence of Humidity: -0.03 % relative O₂ reading per % RH
  • Shelf Life: < 3 months recommended
  • Electrical Connector: Two flying wires with plug on PCB
  • Material in Contact with Media: PVDF, PPS, PTFE, stainless steel
  • Weight: Approximately 33 g

Device Compatibility:

The M-06 sensor is ideal for medical devices and monitoring systems that require flying wire connectors and precise current output for oxygen detection, including ventilators and anesthesia equipment.

The M-06 Medical Oxygen Sensor supports a wide range of devices including EnviteC® OOM107-2, IT-Gambert® M-06, Maxtec® Max-18 (CAG18), Megamed® M1, MSA® (Catalyst Research)    485905, 655262.

Further compatibility extends to Oxitron® 3050, Teledyne® C1R (B 39022) and Vascular Technology® 103103 and Ventrex®    V-02,  Ventronix® 5525, 5528, 5529.


Key Features:

  • High signal stability with low interference from anesthesia gases
  • Broad oxygen measurement range from 0 to 100 Vol.%
  • Consistent and fast response time (T90 < 20 seconds)
  • Durable sensor life exceeding 300,000 Vol.% hours
  • Excellent linearity and repeatability
  • Standardized grey flat base with flying wire connector (Part No. 41 00 08)
  • Resistant to environmental humidity and temperature fluctuations

Download the M-06 Complete Specifications Sheet

Download the M-06 Material Safety Data Sheet

View full details